Primary head for
combination |
MAGMAX® series Electromagnetic flowmeters:
EGS1000F, EGS2000F, EGS4000F, EGS5000F, EGS6000F etc. |
Excitation |
Square wave |
Flow range |
Flow velocity
Max. 0 to 12 m/s
Min. 0 to 0.3 m/s |
Materials |
Housing: Aluminum alloy
Cover: Aluminum alloy |
Painting |
Polyurethane resin paint |
installation |
Wall installation
(Option : Fittings for 2B pipe installation) |
Accuracy |
Indication and Pulse output
1) Primary heads for combination
EGS2000, EGS4000,
EGS5000 (Nominal size : 10 to 100 mm), EGS6000
For velocity ≥ 0.33 m/s : ±0.5% of reading
For velocity < 0.33 m/s : ±0.2% of reading + velocity error of ±0.001 m/s
2) Primary heads for combination
EGS1000, EGS5000 (Nominal size : 2.5 to 6 mm)
For velocity ≥ 1 m/s : ±0.5% of reading
For velocity < 1 m/s : ±0.4% of reading + velocity error of ±0.001 m/s
Current output
Additional error of ±0.01 mA be added onto displey and pulse output. |
Indicator |
Blue dot matrix LCD with backlight, 128×64 pixel.
2 kinds of screen changeable, and possible to display up to 3 lines per screen. |
Output |
- Current output:
- 4 to 20 mA DC
- Pulse output:
- Open collector output
- Status output:
- Open collector output
(One of the following contents selectable: No status output, identification of flow direction, over range, error, flow alarm, identification of range, and empty detection)
|
Other functions |
Low cut-off, damping time constant, isolation of input and output, customer's free measuring unit setting, automatic zero adjustment, bidirectional flow measurement, double-range measurement, switching of excitation current frequency, self-diagnosis, memory save for power failure, output test, touch sensor setting, and HART® communication |
Power Supply |
100 to 230 V AC
24 V DC |
Protection class |
IP66/67(IEC 60529) |