VDT

Flow Measurement
Differential pressure Flowmeters
Wafer-Cone® Flowmeters

VDT series is the indicator integrated type Wafer-Cone® differential pressure flowmeter; VH series Wafer-Cone® flowmeter and DT series multi digital differential indicator are integrated into one flowmeter.
Its principle is based on the Bernoulli's theorem like orifice flowmeter. The V-cone inside pipe throttles flow and generates differential pressure corresponding flow rate.
The precision cast body made in lost wax process has a simple and rigid construction. Shorter straight runs and lower pressure loss than orifice save your construction cost and energy.

Catalogs and Brochures

*Specifications are subject to change without prior notice.

Features

  • Easy installation with self- centering mechanism
  • Direct mounting of compact differential pressure indicator requires no impulse piping
  • Less than 1/5 of orifice straight runs
  • Stable low differential pressure measurement allows wide rangeability
  • Stable low differential pressure measurement allows low pressure loss
  • Durable structure against wear or adhesion and maintenace free with stable operation
  • Easy-to-change flow direction at flield
  • Easy-to-read big display and versatile indication functions

Applications

  • Flue gas flow management
  • HVAC(Heating ,ventilation and Air conditioning) system
  • Water treatment facilities
  • Refuse incinerator plants
  • Co-generation plants

Specifications

Measuring medium Liquids, Gases (Steam can not be measured)
Nominal diameter 25A to 100A
Flow Range Water : 
Max. 0 to 119.73 m³/h (at 20°C)
Min. 0 to 5.51 m³/h (at 20°C)

Air : 
Max. 0 to 7591 m³/h(nor) (at 0°C, 0.5 MPa)
Min.0 to 77 m³/h (nor) (at 0°C, 0 MPa)
Fluid Temperature Max. 70°C
Fluid Pressure 0.5MPa max.
Process Connection JIS10K/20K, ANSI150/300, DIN PN16/40, GB PN1.6/4.0
Accuracy ±1.5% to 2.5% F.S.

Contact usProduct Inquiry

We will answer your product inquiries and technical questions.