VNT

Flow Measurement
Differential pressure Flowmeters
Wafer-Cone® Flowmeters

VNT series is the transmitter integrated type Wafer-Cone® differential pressure flowmeter; VH series Wafer-Cone® flowmeter and precision transmitter are integrated into one flowmeter. Its principle is based on the Bernoulli's theorem like orifice flowmeter. The V-cone inside pipe throttles flow and generates differential pressure corresponding flow rate. The precision cast body made in lost wax process has a simple and rigid construction. Succeeding various features of V-cone flowmeter, it realized low cost flow measurement. It measures liquids, gases and saturated steam with high temperature.

Catalogs and Brochures

*Specifications are subject to change without prior notice.

Features

  • Easy installation with wafer construction
  • Direct mounting of compact differential transmitter requires no impulse piping
  • Measuring liquids, gases and steam
  • Less than 1/5 of orifice straight runs
  • Stable differential pressure at low flow rate
  • Stable low differential pressure measurement allows wide rangeability
  • Stable low differential pressure measurement allows low pressure loss
  • Durable structure against wear or adhesion and maintenace free with stable operation

Applications

  • Steam and water flow management
  • Flue gas flow management
  • HVAC(Heating ,ventilation and Air conditioning) system
  • Water treatment facilities
  • Refuse incinerator plants
  • Co-generation plants

Specifications

Measuring medium Liquids, Gases, Saturated steam
Nominal diameter 25A, 40A, 50A, 65A, 80A, 100A
Flow Range
Water: 
Max. 0 to 119.73m ³/h (at 20 °C)
Min. 0 to 5.51m ³/h (at 20 °C)
Air: 
Max. 0 to 10385m ³/h (nor) (at 20°C, 0.99 MPa)
Min. 0 to 77m ³/h (nor) (at 20°C, 0 MPa)
Saturated steam: 
Max. 0 to 10745 kg/h (at 1.6 MPa)
Min. 0 to 103 kg/h (at 0.1 MPa)
Fluid Temperature Liquids: Max.120 C
Gases: Max.120 C
Saturated steam: Max.204.3 C
Fluid Pressure Liquids: 2 MPa max.
Gases: Less than 1MPa
Saturated steam: 1.6MPa max.
Process Connection JIS10K/20K, ANSI150/300, DIN PN16/40, GB PN1.6/4.0
Accuracy ±1.0% to 1.5% F.S.

Contact usProduct Inquiry

We will answer your product inquiries and technical questions.