O3000

Flow Measurement
Differential pressure Flowmeters
ORIFLOMETER

The O3000 flowmeter consists of an orifice plate and a metal tube variable area flowmeter (AM3000). It is designed to measure bypass flow by using a small flowmeter attached to the branch pipe, and thus to enable the measurement of flow rates in large pipes at low cost. The indicators are selectable from the local indication type, electric transmitter type, and electric transmitter type with HART® communication.

Catalogs and Brochures

*Specifications are subject to change without prior notice.

Features

  • Cost effective
    The measuring method using an orifice plate enables the measurement of flow rates in medium- to large-size main pipes at low cost.
  • Omni-direction support (except O3□□□- AP)
    Supports all directions from bottom to top, top to bottom, left to right, and right to left.
  • HART® communication
  • Explosion-proof
    Certified by TIIS, KOSHA, NEPSI, ATEX and IECEx.
  • Indicator protection category: IP67

Specifications

Measuring medium liquids (up to viscosity 3 mPa·s)
gases in general (not suitable for slurry and steam)
Nominal diameter 15A to 300A
Flow range water (density 1.0g/cm³, viscosity 1.0 mPa·s)
 Max.: 64 to 1000 m³/h (Diff. pressure: 50 kPa)
 Min.: 0.27 to 1.8 m³/h (Diff. pressure: 30 kPa)

air (0℃, 1 atm)
 Max.: 1700 to 26000 m³/h(nor) (Diff. pressure: 50 kPa)
 Min.: 5.5 to 53 m³/h(nor) (Diff. pressure: 40 kPa)
Fluid Temperature −20℃ to 120℃ (general type)
−20℃ to 200℃ (high-temperature type)
Fluid Pressure 2 MPa max.
Process connection
Screw connection: 
Rc tapered female thread and NPT female thread,
pipe size: 15 A (1/2") to 100 A (4")
Flange connection: 
JIS5KFF/10KFF·RF/20KRF,
ANSI/ASME/JPI class:150/300RF,
pipe size: 15 A (1/2") to 300 A (12")
Wafer connection: 
JIS5K/10K/20K,
ANSI/ASME/JPI class: 150/300,
pipe size: 15 A (1/2") to 300 A (12")
Accuracy ±5% F.S.

Contact usProduct Inquiry