contact us

Flow PurgemeterP-400

Purgemeter P-400

P-400 PDF

-Advice for your product selection Catalog PDF

*Specifications are subject to change without prior notice.

The P-400 is a corrosion-resistance type purgemeter with all stainless steel construction. Panel installation and flange connection are possible.

Major Applications

Corrosive services

Standard Specifications

Measuring fluid Gases
Liquids
Measuring range
Air:  
Min. 80 to 800 mL/min (nor)
Max. 6 to 60 L/min (nor)
Air at 0°C, 0MPa(1atm)
Water:  
Min. 5 to 50 mL/min
Max. 0.2 to 2 L/min
Water with a density of 1.0g/cm³ and viscosity of 1.0mPa·s

·When selecting a flow range, refer to "Index & Quick Reference for P Series Purgemeters" (TG-S0001).

·When selecting a flow range,refer to the standard flow rate table.
Range ability 10:1
Indication accuracy ±3% F.S.
Fluid pressure Max. 1MPa(Max. 0.5MPa for PVC)
Fluid temperature Max. 120°C (Depends on the gasket material)
(Max. 60°C for PVC)
Material
Wetted part:  
SCS14/SUS304, SCS14/SUS316, PVC
Tapered tube:  
Heat-resistant glass
Gasket:  
Nitrile rubber (NBR)(Max. 80°C)
Chloroprene rubber (CR) (Max. 80°C)
Fluoro rubber (Max. 120°C)
PTFE(Max. 120°C) not applicable to PVC body

·The maximum fluid temperature for each gasket material may vary depending on usage and ambient conditions.
Mounting plate:  
SUS304
Cover:  
Acryl, SUS304
Process Connection Rc: 1/4"(Standard) , 1/8", 3/8", 1/2"
NPT: 1/8", 1/4", 3/8", 1/2"
Flange: 10A, 15A(1/2"), 20A(3/4"), 25A(1")
Mounting Lock nut mount on panel front (Standard)
Flange connection
With stand
Mass approx. 0.9kg