A-100/700

Flow Measurement
Custom-made Products
Direct Observation Type flowmeter

A-100/700 are variable area flowmeters and consist of metal tapered and glass extension.The movement of float can be visually checked through upper sight glass and the flow rate is indicated by the position of float and the scale plate on the glass tube. Local indication version A-100 and alarm contact version A-750 are available.

Catalogs and Brochures

*Specifications are subject to change without prior notice.

Features

  • Simple construction and cost effectiveness.
  • In addition to the standard Bottom to Top side type, straight Bottom to Top type can also be arranged.
  • Alarm contact version is available.

Specifications

Measuring medium Liquids or Gases
Nominal diameter 15 to 150A
Flow range Water
Max. 20.4 to 204m³/h
Min. 0.01 to 0.1m³/h

Air
Max. 641 to 6410m³/h(nor)
Min. 0.3 to 3m³/h(nor)
Fluid Temperature Max. 120°C
Fluid Pressure 1.4 MPa max.
Process Connection JIS 10KRF flange
Accuracy ±1.5% F.S.

Contact usProduct Inquiry

We will answer your product inquiries and technical questions.