P-900

Flow Measurement
Purgemeters
Other lineup

The P-900 is a slim purgemeter with an all stainless-steel body. Reducing the material content has achieved a low price and quick delivery.

Catalogs and Brochures

*Specifications are subject to change without prior notice.

Major Applications

  • Corrosion-resistant equipment

Specifications

Measuring medium Gases
Liquid
Nominal diameter Rc: 1/4" (Standard)
NPT: 1/4"
Flow range Air
P-901:  
Max. 12 to 60 L/min (nor)
Min. 80 to 800 mL/min (nor)
P-902:  
Max. 6 to 60 L/min (nor)
Min. 80 to 800 mL/min (nor)
Water
 
Max. 0.25 to 2.5 L/min
Min. 5 to 50 mL/min
·When selecting a flow range, refer to "Index& Quick Reference for P Series Purgemeters" (TG-S0001).
·When selecting a flow range,refer to the standard flow rate table.
Fluid temperature Max. 120°C
Fluid pressure 0.8MPa max.
Process Connection Rc, NPT
Accuracy P-901: ±5% F.S.
P-902: ±3% F.S.

Contact usProduct Inquiry

We will answer your product inquiries and technical questions.