MAGMAX EGC300F is a field installation type converter which is used in combination with MAGMAX® series electromagnetic flowmeter primary head.
The fluid noise during measurement has been reduced by the excitation method. The method enables to raise the frequency to twice as high as the commercial power frequency.
Improved self-diagnosis functions such as empty detection, monitoring of detector, etc. are provided.
* MAGMAX® is registered trademark of the TOKYO KEISO CO.,LTD.

Features

  • · Various high functions equipped:
    Pulse output, bidirectional flow measurement, double range, output of status such as flow alarm, and control input provided as standard.
  • · High accuracy of ±0.5% of reading
  • · High speed data processing for quick response. Suitable for batch control process and pulsating flow.
  • · Field current frequency can be adjusted up to twice of main frequency which is effective for slurry noise rejection.
  • · Easily visible and blue dot matrix LCD indicator offers flexible indication.
  • · Quick set-up function for easy data setting/change such as scale range, pulse rate, etc.
  • · All setting parameters can be set/changed by an infrared touch sensor without opening the housing cover.
  • · High pulse rate up to 10 kHz offers high resolution for short time batch process control.
  • · HART® communication provided as standard.

Main Specifications

Primary heads combined
with EGC300F
MAGMAX® series Electromagnetic flowmeters:
EGS1000F, EGS2000F, EGS4000F, EGS5000F, EGS6000F etc.
Excitation method Square wave
Measuring range
(Flow velocity)
Max. 0 to 12 m/s
Min. 0 to 0.3 m/s
Indicator Blue dot matrix LCD with backlight, 128×64 pixel.
2 kinds of screen changeable, and possible to display up to 3 lines per screen.
Indication Instantaneous flow rate, flow velocity, totalizing flow volume, conductivity, and coil temperature
Output
Current output: 
4 to 20 mA DC
Pulse output: 
Open collector output
Status output: 
Open collector output
(One of the following contents selectable: No status output, identification of flow direction, over range, error, flow alarm, identification of range, and empty detection)
Input
Control input: 
Voltage input
(One of the following contents selectable: No control input, signal hold, signal lock to 0%, total counter reset, error reset, and range selection)
Accuracy
Pulse output: 
Primary heads for combination: EGS2000F, EGS4000F, EGS5000F (nominal size: 10 to 250 mm),  EGS6000F

Primary heads for combination: EGS1000F, EGS5000F (nominal size: 2.5 to 6 mm)
±0.5% of reading (flow velocity ≥ 1 m/s)
±0.4% of reading + flow velocity error of ±0.001 m/s
(flow velocity < 1m/s)
Current output: 
Additional error of ±0.01 mA to be added to the pulse output accuracy.
±0.5% of reading (flow velocity ≥ 0.33 m/s)
±0.2% of reading + flow velocity error of ±0.001 m/s
(flow velocity < 0.33 m/s)
Other functions Low cut-off, damping time constant, isolation of input and output, customer's free measuring unit setting, automatic zero adjustment, bidirectional flow measurement, double-range measurement, switching of excitation current frequency, self-diagnosis, memory save for power failure, output test, touch sensor setting, and HART® communication
Materials
Housing: 
Aluminum alloy (polyurethane resin coated)
Cover: 
Polyamide resin
Supply voltage /
Power consumption
100 to 230 V AC (85 to 250 V AC) / Approx. 22VA
Option: 24 V DC (9 to 31 V DC) / Approx. 12W
Protection class 100 to 230V AC
24V DC
Explosionproof
specification
ATEX Directive 94/9/EC
KEMA05 ATEX2053
II2 GD EEx d e [ia] IIC T6