Capable of maximum 15 years' continuous measurement with an inhouse battery, ETM3070 series electromagnetic volume totalizing meter has attained an eco-friendly and reliable high-performance measurement.
The measuring tube is Lined with Rilsan® widely used for coatings for the inside of city water pipes, the tube with reduced size has significantly increased the accuracy in the domain of low flow measurement.
This flowmeter is applicable for the vast variety of services in water related industries.
Measuring medium | Drinking water, Tap water, Raw water, Irrigation water |
---|---|
Nominal diameter | 25 to 200 mm |
Flow range | Max. 15.9 to 1017 m³/h Min. 0.9 to 56.5 m³/h |
Fluid Temperature | 0 to +70℃ |
Fluid Pressure | 1.6MPa max. |
Process Connection | Flange |
Accuracy | Flow velocity 0.5 m/s or more: ± 0.5 % of reading Flow velocity less than 0.5 m/s: ± 0.2 % of reading + velocity error ± 0.0015 m/s |