FlowMeasurement
-
LevelMeasurement
-
Related Instruments
Guidance Download
QR code
* Please scan the QR code with your smartphone to access this website page.
MAGMAX EGM7300C adopts flat capacitance detection type electrodes which are located outside of measuring tube made of ceramics instead of the conventional liquid contacting metallic electrodes for detection of flow velocity.
Thanks to the capacitance detection and non-wetted electrode design, EGM7300C has achieved the stable measurement of very low conductivity liquids, highly concentrated slurries and adhesive liquids.
With the self-diagnosis function EGM7300C has intensified its reliability by monitoring status of primary head.
Measuring medium | Liquids |
---|---|
Nominal diameter | 25 to 100 mm |
Flow range | Max.: 0 to 339 m³/h Min.: 0 to 0.531 m³/h |
Fluid Temperature | -40 to +100°C |
Fluid Pressure | 4MPa max. |
Process Connection | Wafer type, sandwiched between following flanges |
Accuracy | For flow velocity ≥ 0.33m/s: ±0.5% of reading For flow velocity < 0.33m/s: ±0.2% of reading + velocity error ±0.001 m/s |