The MAGMAX EGM4050C is a compact electromagnetic flowmeter consisting of the flange type EGS4000 primary head, which is lined with PFA or PTFE, from the proven MAGMAX series, and the EGC050 converter mounted on it.
The enhanced self-diagnosis unit can detect empty flow and monitor the status of the primary head.
Nominal sizes of 10mm to 1000mm are available. The EGM4050C is ideal for chemicals and many other applications.
Measuring medium | Liquids |
---|---|
Nominal diameter | 10 to 1000mm |
Flow range | Max.: 0 to 33928 m³/h Min.: 0 to 0.085 m³/h |
Fluid Temperature | -40 to +140 ℃ |
Fluid Pressure |
Up to the rated pressure of flanges *Allowable temperature and pressure depend on lining materials. |
Process Connection | Flange |
Accuracy | For velocity ≥ 0.5m/s: ±0.5% of reading For velocity < 0.5m/s: velocity error ±2.5mm/s |