The STK2000 and STK7400 are high-accuracy, high-performance,flapper-type flowmeters. The STK2000 is a local indication type,and the STK7400 is a local indication + alarm contact type. Both flowmeters can be compactly mounted on horizontal pipework.
· STK2000: Local indication type
· STK7400: Local indication + alarm contact type
Measuring medium | Water, and liquids whose viscosity and density are comparable to those of water |
---|---|
Nominal diameter | 15A to 300A |
Flow range | 1.5 to 600 m³/h |
Fluid Temperature | -20 to 120°C |
Fluid Pressure | 1.0 MPa max. |
Process Connection | Flange (JIS 10K FF or ASME Class 150) |
Accuracy | ±3.0% F.S. |