Introduction of Capacitance detection type Compact
Electromagnetic Flowmeter[4]/[4]

MAGMAX MGM5090K-CAP

Microsystems Technology

Three layers of ceramic tapes (LTCC) The circuit elements for the preamplifier are mounted on this top layer. The capacitive electrodes and the preamplifiers for the signal pickup are integrated on the ceramic flow tube.

Ceramic tape
Pre-amplifier mounted on Ceramic tape

Ceramic pipe
   Ceramic tube with Pre-amplifier assembly

CAPAFLUX Pre-Amp.

Between the capacitive electrodes and the preamplifiers pick up the noises. Due to this Microsystems Technology, MGM5090K-CAP does not have problems with microphonic effects, and 5 times less noise from piping vibration than other instruments which does not use Microsystems technology.

 

CAPAFLUX Amplifier