FlowMeasurement
-
LevelMeasurement
-
Related Instruments
Guidance Download
QR code
* Please scan the QR code with your smartphone to access this website page.
This monitoring system consists the radar level gauge TA840,cargo temperature and inert gas pressure transmitter I-NODE, intrinsically safe power supply IS-POWER M1, control module CONTROL M1.
This system communicates with Multi-monitor SuperDIR series to measure and monitor each cargo level, temperature and pressure.
This system is suitable for measurement and control of liquid cargos at crude oil tankers and product/chemical carriers.
TA840 radar level gauge has been in operation for over 15 years and more than 6,000 units are installed on board all kind of ships and platforms.
Offering the latest upgraded version and ensuring the required stability and reliability of the cargo measurement and monitoring system.
TA840 RADAR LEVEL GAUGE
Measuring range | 0.5m to 42m |
---|---|
Measuring accuracy | ±10mm |
Intrinsic safety approval | Exia[ia]IIB T6…T5 or IIC T6…T5 (ATEX standard) |
Protection class | IP66/67 |
Maximum tank pressure | 1bar |
Operating temperature | -40°C to +70°C |
I-NODE TEMPERATURE & PRESSUR TRANSMITTER
Material | Housing SUS 316L Temperature sensor SUS 316L Pressure sensor SUS 316L |
---|---|
Measuring range | Temperature -40°C to + 250°C Pressure 1600hPa |
Measuring accuracy | Temperature ±2°C Pressure ±1% F.S |
Operating tamperature | - 40°C to+ 85°C |
Intrinsic safety approval | Exia[ia]IIB T4 or IIC T4 (ATEX standard) |
Protection class | IP66/67 |
IS-POWER M1 INTRINSICALLY SAFE POWER SUPPLY
Power input | 85 - 264Vac / 50 to 60Hz |
---|---|
Power output | IIC: 11.0Vdc、IIB: 12.2Vdc |
Consumption | 30W (max) |
Output channel | Power 3ch. & Serial (RS-485) 3ch. |
Operating temperature | -25°C to 70°C |
Intrinsic safety approval | Exia[ia]IIB or IIC (ATEX standard) |
CONTROL M1 CONTROL MODULE
CPU & Memory | 32 bits ARM7 RAM: 32MB FLASH: 1.5MB |
---|---|
Power input | 24Vdc |
Consumption | no 4-20m A AI 12W 32ch. 4-20 mA AI 30W |
Serial (RS-485) port | 16ch. |
Input/Output channel | AI( 4-20mA) 32ch., DI-DO 32ch. |
Operating temperature | 5℃ to 70℃ |