contact us

Level Digital tank data indicatorDIR-530

DIR-530

DIR-530 PDF

*Specifications are subject to change without prior notice.

Developed from the well accepted DIR-500, the RoHS compatible DIR-530 is a panel mounted type compact indicator which receives signals from TOKYO KEISO's 2-wire digital tank data transmitters and tank top type level gauges.
It is best suited for the following services:
 (1) Receiving instrument for full time monitoring of a tank
 (2) Inexpensive receiving instrument for moderate size tank yard with a few tanks
 (3) Interfacing with supervisory system
At low cost, DIR-530 constitutes the simple, reliable, accurate digital monitoring system of the tank yard in combination with TOKYO KEISO's various tank monitoring 2-wire transmitters.

Features

  • · DIR-530 has 2 of 4 to 20mA outputs and 2 of alarm relay outputs when used as one tank monitoring
  • · DIR-530 receives Max. 4 transmitters with 2- wire system common to power and single direction digital transmission
  • · DIR-530 receives Max. 16 transmitters with 2 separate wirings of power and bi-direction digital transmission
  • · DIR-530 is connected to supervisory systems such as personal computer, DCS and sequencer via pre-installed serial and parallel communication ports, RS-232C or RS-485 with Modbus-RTU
  • · DIR-530 is interchangeable with the current 1 tank receiving instrument i.e. TOKYO KEISO's DIR-200 and DIR-400 receivers, except alarm reset input of DIR-200. It makes your factory renovation easier.
  • · DIR-530 indicates the operating status of itself as well as level and temperature at the same time
  • · All operation parameters are set from menu selection through three key switches
  • · Compact 96 x 96 mm size

Short Specifications

Connectable tanks Max. 16 per multi-monitor
Connectable transmitters TOKYO KEISO’s single direction type
Indication Red LED
Tank No.: 
1 digit
Level: 
6 digits Signal from FW-9000 is indicated in unit of 0.1mm
Temperature in °C: 
4 digits with one place of decimal
Status: 
2 digits
Indicates tank alarm/error/displacer status by symbols during level indication

Others: 
24 pieces of LED
Indicates operation mode/displacer status/alarm status during level indication
Operation
Key operation: 
UP, WRITE, ENTER
Key specifications: 
Membrane type with 8mm in diameter
Host interface RS-232C or RS-485
Power supply 85 to 250V AC, 50/60Hz
Installation Panel mount