TGR4500

Guided Radar with 2-wire system Micro Pulse Level Meter

TGF2200

The TGF2200 series is a unique 2-wire continuous level-measuring instrument using TDR technology.

The simple and compact design suitable for tank-top installation with no moving parts has a high cost performance with the maintenance-free and low cost installation by the simple 2-wire loop powered system. Thanks to the coaxial probe, single probe and twin probes this continuous level meter is applicable to wide services including liquids, slurries, powders and granules. The keypad operation on the front display allows easy parameter setting including zero point adjustment and measuring range. The micro pulse level meter is suitable for tank and silo inventory for liquids and powders as well as level controls of the intermediate or underground tanks.

 

catalog download

Specifications are subject to change without prior notice.

Features

· 2-wire loop powered system with less cable and low installation cost
· Wide applications by TDR method
· Elimination of false signals by DPR (Dynamic Parasite Rejection)
· From -50°C to 300°C and from vacuum to 4.0 MPa
· No influence from changes in temperature, pressure or density
· The probe can be used in segment to make it easy to use
· Measuring Max. 40 m in liquids, powders and granules
· Horizontal or vertical housing position to make the display easy to read
· Remote converter allows a free selection of installation
· Easy checking and changing of parameters without opening the cover
· Quick coupling system permits removal of the housing and full rotation
· No moving parts and maintenance free

STANDARD SPECIFICATION

Measuring object

Measuring material : Liquids, slurries, powders, granules
Measuring principle : Time Domain Reflectometry (TDR)

Measuring variables : Level, distance, volume, mass

Probe type

Single rod probe ( Φ 8 mm) with PVDF sheath of Φ 16 mm
Twin rod probe (2×Φ 8 mm)
Single cable probe ( Φ 2 mm, Φ 4 mm, Φ 8 mm)
Twin cable probe (2× Φ 4 mm)

Coaxial probe ( Φ 22 mm)
Outputs 4 to 20 mA DC or 3.8 to 20.5 mA DC
Accuracy

±10 mm for less than 10m and ±0.1% of the reading for 10m or more
TBF mode : ± 20 mm

Powder and granule measurement : ± 20 mm
Temperature of process connection

-50 to +150℃(Standard type)

-50 to +300℃(High temperature type : Φ 2mm Single cable probe)
Pressure 0 kPa(abs)to 4.0MPa
Measuring conditions
Dielectric constant 

: Min. 1.4 for coaxial probe

: Min. 1.1 for TBF mode

Max. dia. of granules : 5 mm or less in diameter
Ambient temperature

-40 to +80℃(Without display)

-20 to +60℃(With display)
Protection class

IP66 / IP67〔IEC60529〕

NEMA250: NEMA type 4X (Converter housing,  6P(Probe housing)
Power supply voltage

Rated voltage : 24 V DC
Allowable range : 11.5 to 30 V DC for non-explosion proof and intrinsically safe

Allowable range : 13.5 to 36 V DC for flame proof
Materials

Housing : Aluminum, Stainless steel 316L
Process connection : Stainless steel 316L, Hastelloy C-22
Probe : Stainless steel 316, Stainless steel 316L, Hastelloy C-22

Seal : FKM, FPM, EPDM, Karlez6375
Process connection

Thread : G male thread, NPT male thread

Flange : JIS RF flange, ASME RF flange
Display LCD display / 4 button operation key

 