The STK2000 and STK7400 are high-accuracy, high-performance,flapper-type flowmeters. The STK2000 is a local indication type,and the STK7400 is a local indication + alarm contact type. Both flowmeters can be compactly mounted on horizontal pipework.
· STK2000: Local indication type
· STK7400: Local indication + alarm contact type
Measuring fluid | Water, and liquids whose viscosity and density are comparable to those of water |
---|---|
Measurement range | 1.5 to 600 m³/h |
Fluid temperature | -20 to 120°C |
Fluid pressure | Max. 1.0 MPa |
Process connection | Flange (JIS 10K FF or ASME Class 150) |
Accuracy | ±3.0% F. S. (factory calibration with 20°C water) |
Flow direction | Horizonal or vertical |