Liquid in high temperature up to 150°C(max.) can be measured by W-3000 Mini-Wheel Flowmeter having the special cooling fin construction, based on W-2000 series which has been warmly accepted. This flowmeter is suitable to be installed in the chiller devices for semiconductor plants.
Flow measurement and control of solvent for chiller devices such as florinert, galden and many kind of liquids.
Measuring medium | Various liquids (Fluorinert, Galden etc.) |
---|---|
Nominal diameter | 3/8 to 3/4 |
Flow range | Max. 6 to 60L/min Min. 0.5 to 3L/min |
Fluid Temperature | Max. 150°C |
Fluid Pressure | 1.0 MPa max. |
Process Connection | Rc thread, tube end |
Accuracy | ±3% F.S. ±5% F.S. (for flow range 0.5 - 3L/min) |