FlowMeasurement
-
LevelMeasurement
-
Related Instruments
Guidance Download
QR code
* Please scan the QR code with your smartphone to access this website page.
The O7000 flow meter consists of an orifice plate and a metal tube variable area flow meter (AM7000).
By measuring a bypass flow of the" large sized" pipes with a" small sized" flow meter, the flow rate in the large pipes can be measured at low cost.
The robust and reliable local indicator can be equipped with the electric output, local flow integration with pulse output, alarm output and communication function to meet various applications.
Measuring medium |
Liquids (Max. viscosity 3 mPa·s) and Gasses, not suitable for slurry and steam |
---|---|
Nominal diameter | 50A to 500A |
Flow range | Liquids (in case of density: 1.0 g/cm³ and viscosity: 1.0 mPa·s) Max. 200 to 3000 m³/h (size: 500 mm, at DP = 60 kPa) Min. 3 to 25 m³/h (size: 50 mm, at DP = 40 kPa) Gases (in case of temperature: 0 °C, and 1 atm) Max. 4900 to 72000 m³/h (nor) (size: 500 mm, at DP = 60 kPa) Min. 80 to 710 m³/h (nor) (size: 50 mm, DP = 40 kPa) |
Fluid temperature | -20°C to 200°C |
Fluid pressure |
For JIS10K class (1.4 MPa at max.120°C, 1.2 MPa at max.200°C) The maximum allowable pressure is subject to its temperature Complying with the relevant flange ratings. Consult us for higher pressure services. |
Process connection |
JIS 5K, 10K, 20K ANSI or JPI CLASS 150, 300, Consult us for others. |
Accuracy | ±3% F.S. |