O-100 is series of Orifice bypass flowmeter. The flow through the main pipe is by -passed by an orifice plate. The bypassed flow is indicated by small sized glass tube variable area flowmete flow measurement through main pipe.
Measuring medium | Liquids (Viscosity: up to 3mPa·s) and Gases (Not suitable for slurry and steam) |
---|---|
Nominal diameter | 50A to 500A |
Flow range | Liquids (in case of density: 1.0g/cm³ and viscosity: 1.0mPa·s) Max. 600 to 3000 m³/h (Size: 500mm, at DP=60kPa , Stainless float) Min. 0.35 to 1.4 m³/h (Size: 50mm, at DP=10kPa , Resin float) Gases (in case of temperature: 0°C and pressure: 0MPa) Max. 9000 to 45000 m³/h(nor) (Size: 500mm, at DP=20kPa) Min. 6.25 to 25m ³/h(nor) (Size: 50mm, at DP= 5kPa) |
Fluid temperature | Max. 120°C (Allowable thermal shock 80°C) |
Fluid pressure | 1.0 MPa max. |
Process Connection | JIS 5K/10K, ANSI/JPI CLASS 150/300 and Others. |
Accuracy | ±3% F.S. |