C series Purge sets keeps flow of gases or liquids even if the
supply or load pressure varies.
C series Purge sets consists of C type constant flow valve and suitable flowmeter.
Various sizes are available.
Constant Flow Valve Type | C-11 P₁(INLET) Variation C-12 P₂(OUTLET) Variation |
C-21 P₁(INLET) Variation C-22 P₂(OUTLET) Variation |
C-31 P₁(INLET) Variation C-32 P₂(OUTLET) Variation |
C-41 P₁(INLET) Variation C-42 P₂(OUTLET) Variation |
---|---|---|---|---|
Measuring medium | Gases only | Gases and Liquids | ||
Nominal diameter | 1/8 | 1/4 | 3/8 | 1/2 |
Flow range | Air 0MPa、0℃ | |||
Max. 0.3 ~ 3 L/min(nor) Min. 10 ~ 100 mL/min(nor) |
Max. 5 ~ 60 L/min(nor) Min. 0.1 ~ 1 L/min(nor) |
Max. 15 ~ 150 L/min(nor) Min. 5 ~ 50 L/min(nor) |
Max. 30 ~ 300 L/min(nor) Min. 15 ~ 150 L/min(nor) |
|
Water Density 1.0 g/cm³、Viscosity 1.0 mPa・s | ||||
Max. 0.2 ~ 2 L/min Min. 5 ~ 70 mL/min |
Max. 0.5 ~ 5 L/min Min. 0.2 ~ 2 L/min |
Max. 1 ~ 10 L/min Min. 0.5 ~ 5 L/min |
||
Fluid temperature | 120°C Max. | |||
Fluid pressure | 0.7MPa Max. | 1MPa Max. | 0.8MPa Max. | |
Process connection | Rc | |||
Accuracy | ±3% F.S. | ±5% F.S. |