contact us

Flow All Fluororesin Flowmeter AC-T

AC-T

AC-T PDF

*Specifications are subject to change without prior notice.

AC-T is a series of direct indication type variable area flowmeter with fluororesin construction for liquid flow measurement. In addition to local flow indication, an alarm contact is additionally available for flow alarm function.

Standard Specifications

Measuring object Water (Density 1.0 g/cm³, Viscosity 1.0 mPa·s)
Available size 15A and 20A
Scale range
Min.: 
2 to 20 L/min. [15A or 20A]
Max.: 
5 to 50 L/min. [20A]
Max.Op.Press. 0.49 MPa (At room tremp.)
Acceptable pressure lowers for higher liquid temp.(ex. 0.2MPa at 80°C)
Consult factory for further details.
Max.Temp. 90°C (At Op.Press.: 0.15 MPa)
Process connection
Standard: 
15A or 20A Welding mount or Rc thread
Option: 
Other connection fittings on request
Flow direction Bottom to Top
Indication accuracy ±3%F.S
Range ability 10 : 1
Material Fluoric material construction
(Refer to [STANDARD MATERIAL CONSTRUCTION] for details.)
Alarm point 1 point high or low additionally available Reed switch SPST